DP
Series |

Designed and tested to provide 100% clean, dry, oil-free compressed
air at -40°c atmospheric dew point, to safeguard your valuable
pneumatic equipment.
Trident Dryers are available
in 19 models to suit your requirement. They work with pressures from 4
kg/cm2(g) to 70 kg/cm2(g) and flow upto 1920
m3/hr.
|
|
Operation |
|
|
Prefiltration |
The
moisture laden compressed air passes through the pre filter. Here
moisture load is reduced through coalesence. Condensation is removed
through the drain valve ADV1. At the oil filter (2) oil vapors are
removed completely, small levels of oil/water condensation are purged
through the valve ADV2. Compressed air is then passed through a 3 way
valve into Tower. |
|
Drying |
The
Towers are filled with Activated Alumina as desiccant (Molecular sieve
available as option). When air passes through Tower 1 which consists of
"DRY" Dessicant, it gets completely dried, and passes through check
valve and After Filter(3). At the after filter, Desiccant fines are
removed. Therefore dry compressed air passes out at the
outlet. |
|
Regeneration |
Regeneration takes place in 2 stages a)
De-pressurisation b) By passing Dry air. Tower II consists of fully
moist desiccant at pressure. This is suddenly De-pressurised by opening
the purge valve. Water molecules weep out of the desiccant and appear on
the surface. "Super Dry" purge air passes through the Regeneration
"Nozzle" and the desiccant bed thereby completely carrying away the
water molecules. Tower 2 gets regenerated and is ready for the next
drying cycle |
|
Salient
Features |
Purge economiser, an energy saving device
reduces purge loss to as low as 50%.
Programmable Controller, with clear functional displays, ensures uninterrupted operation even
while tower changeover.
Automatic drain valves in pre and oil filter to reduce moisture
load and to ensure life of
desiccant at no extra cost.
All
new Microprocessor based controller has a unique purge economiser. The
dryer load can be manually set. It can also accept upto 3 compressor
load/unload contact and compute dryer load dynamically. The purge
is set accordingly. The controller also accecpts a pressure
input and purge air is controlled
accordingly. |
| Application |
Instruments
Machines
Paint
shop Textile
Machines Pharma
|
|
Specification |
|
Model |
Inlet Flow
(m3/hr) |
End
Connection |
Dimensions
(mm) |
Weight
(kg) |
|
Height |
Width |
Depth |
|
DP -
72 |
72 |
3/4"
BSP |
1680 |
650 |
600 |
195 |
|
DP -
96 |
96 |
1"
BSP |
1855 |
650 |
600 |
230 |
|
DP -
144 |
144 |
1"
BSP |
1855 |
650 |
600 |
230 |
|
DP -
192 |
192 |
1"
BSP |
1980 |
650 |
600 |
380 |
|
DP -
288 |
288 |
1"
BSP |
2030 |
750 |
600 |
440 |
|
DP -
384 |
384 |
1½
BSP |
2200 |
750 |
600 |
550 |
|
DP -
480 |
480 |
2"
NB |
1450 |
1100 |
1100 |
620 |
|
DP -
576 |
576 |
2"
NB |
1850 |
1100 |
1100 |
700 |
|
DP -
768 |
768 |
2"
NB |
1850 |
1200 |
1100 |
850 |
|
DP -
960 |
960 |
2½ NB |
2150 |
1200 |
1200 |
950 |
|
DP -
1440 |
1440 |
3"
NB |
2150 |
1500 |
1300 |
1265 |
|
DP -
1920
|
1920
|
3"
NB
|
2540
|
1500
|
1300
|
1575
|
|
|
Temperature
Correction Factor |
|
|
Pressure
Correction Factor |
|
| Correction
Factor |
|
Corrected Flow |
=
|
Actual Flow
Factor(T) x
Factor(P)
|
Choose the nearest higher model.
Flow volume :275m3 / hr ; Working Pressure :6 kg/cm2 ; Inlet air
temperature :45° c; REFERRING THE GRAPHS :Factor (T) = 0.9;Factor
(P) = 0.88
|
|
Requirement |
|
Flow volume
Factor(T) x
Factor(P)
|
= |
275
0.9 x
0.88
|
= |
347.3m3/hr |
Choose the nearest higher model i.e Model DP
384 |
|
Ordering Method |
Example:
DP 1920 is suitable for 1920
m3/hr with inlet pressure of 7 kg/cm2(g) and temperature of 38°
c. |